Traduciendo...
403

Inverter with Smart Meter: no communication

Fronius · Primo GEN24

¿Qué significa 403 ?

The Fronius Primo GEN24 208-240 inverter, configured for operation with a Smart Meter, has lost communication with the device. This fault specifically refers to configurations where a Smart Meter is essential for the operating mode, thus halting normal inverter function.

Causas comunes

  • No communication with the Smart Meter.
  • Wiring fault (e.g. incorrect or loose cable, crossed data lines).
  • Smart Meter not powered.
  • Incorrect Smart Meter address or settings.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Reconfirm all communication cabling (e.g., RS485) between the Fronius Primo GEN24 208-240 inverter and the Smart Meter is correctly installed, free from damage, and securely terminated.

  2. 2

    Check the power supply to the Fronius Smart Meter to ensure it is receiving adequate voltage and is operational.

  3. 3

    Verify that the Modbus address and baud rate configured in the inverter match the settings of the Smart Meter.

  4. 4

    Inspect the Smart Meter's status LEDs for any indications of error or power loss.

  5. 5

    Power cycle the inverter and the Smart Meter in sequence to reset the communication interface.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas