38

Set Charging Time Cannot Be Reached

Fronius · Perfect Charging

¿Qué significa 38 ?

The charging process is unable to complete within the configured total charging time. This suggests that the battery is taking longer than expected to charge, potentially due to its condition, the charger's limitations, or an incorrect time setting.

Causas comunes

  • The battery's actual capacity is higher than configured, or its internal resistance has increased due to degradation, requiring more time to charge.
  • The charger's output current is lower than expected or limited due to internal conditions or load.
  • The charger is operating at reduced power, extending the required charging duration.
  • An incorrect total charging time parameter has been set, which is too short for the battery and charger capabilities.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the actual capacity of the connected battery against its nameplate.

  2. 2

    Check the charger's current output during the charging process to ensure it is delivering the expected current.

  3. 3

    Review and adjust the configured total charging time parameter in the charger's settings to match the actual battery capacity and charger capabilities.

Ver todos los códigos en este manual (61)
Datos técnicos verificados. Última actualización: March 2026