34

Ah Exceeded

Fronius · Perfect Charging

¿Qué significa 34 ?

The total Ampere-hours (Ah) delivered to the battery during charging has exceeded a predefined limit. This is typically a safety mechanism intended to prevent overcharging based on the expected or configured battery capacity, indicating a mismatch or a faulty measurement.

Causas comunes

  • The actual capacity of the connected battery is significantly lower than expected or configured in the charger's settings.
  • An incorrect Ah limit parameter has been set in the charger, allowing it to deliver more charge than safe for the battery.
  • A malfunction in the charger's current integration or Ah measurement circuit, leading to inaccurate accumulation of delivered charge.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the actual rated capacity of the connected battery against its nameplate or specifications.

  2. 2

    Check the charger's Ah limit parameter and adjust it to accurately match the battery's rated capacity if necessary.

  3. 3

    Perform a diagnostic check on the charger's current measurement and Ah accumulation function to ensure accuracy.