24
Battery Too Hot (External Sensor)
Fronius · Perfect Charging
¿Qué significa 24 ?
The external temperature sensor indicates that the battery temperature is excessively high. This is a critical safety condition that requires immediate attention to prevent thermal runaway, battery degradation, or potential hazards such as fire.
Causas comunes
- High ambient temperature around the battery, leading to increased overall temperature.
- Excessive charging current applied to the battery, generating internal heat faster than it can dissipate.
- Malfunction of the battery's internal cooling system (if equipped) or an issue with the external temperature sensor mounting.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the ambient temperature surrounding the battery and ensure adequate ventilation.
- 2
Reduce the charging current, if adjustable, or temporarily pause the charging process to allow the battery to cool down.
- 3
Ensure the external temperature sensor is properly attached to the battery surface at the recommended location for accurate temperature measurement.
Datos técnicos verificados. Última actualización: March 2026