EXCESS MAXIMUM REV. DATA
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa IE0007 ?
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the control detected a command specifying a value exceeding the maximum allowed speed for a rotational axis or spindle.
Causas comunes
- NC program commands an excessively high spindle speed or rotational axis speed.
- Machine parameter defining the maximum allowable speed is set too low.
- Incorrect gearing or transmission ratio parameters are configured.
- Software limit for maximum speed has been exceeded by the commanded value.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Examine the NC program (S-code, G-code) for any speed commands that exceed the machine's specified maximum limits.
- 2
Verify the machine's maximum permissible spindle speed and feedrate parameters (e.g., Parameter 3701 for spindle max speed) are correctly set.
- 3
Check the gearing or transmission settings in relevant parameters, ensuring they are correctly configured for the commanded speed range.
- 4
Temporarily reduce the commanded speed in the NC program to test if the alarm clears.
- 5
Ensure that the maximum speed set in parameters aligns with the physical capabilities of the motor and spindle/axis.