ABNORMAL PHASE DATA(INT)
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa 361 ?
This alarm on Fanuc Series 0i-D/0i Mate-D with αi/βi Pulsecoders indicates a communication error or ID data error within the built-in Pulsecoder, suggesting a potential failure of the Pulsecoder itself or interference from external noise.
Causas comunes
- Communication error in the Pulsecoder due to faulty internal components.
- ID data error within the Pulsecoder's signal processing.
- Pulse coder failure due to aging or internal defect.
- Electrical noise interfering with Pulsecoder communication.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check for sources of electromagnetic interference (EMI) or noise near the Pulsecoder cable and servo amplifier; mitigate if found.
- 2
Inspect the Pulsecoder cable and its connectors for any signs of damage, proper seating, and secure connections.
- 3
Verify that the Pulsecoder cable shield is properly grounded at the servo amplifier side.
- 4
If noise, cabling, and connections are confirmed to be in good condition, replace the Pulsecoder unit.