- OVERTRAVEL ( SOFT 1 )
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa IE0002 ?
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 1 on the negative side for an axis has been exceeded. This is a software limit violation.
Causas comunes
- NC program error commanding movement beyond the negative software limit 1.
- Incorrect setting of the software limit parameter for negative stroke check 1.
- Manual operation or jog movement exceeding the defined negative software limit 1.
- Tool length offsets or work offsets are incorrectly applied, causing an apparent overtravel.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the NC program for coordinate values or movements that exceed the defined negative software limit 1 for the affected axis.
- 2
Verify the parameter setting for the negative software limit 1 for the specific axis, ensuring it is correctly configured.
- 3
Ensure that tool length offsets or work offsets are accurately entered and do not cause an overtravel condition.
- 4
In manual mode, jog the affected axis in the positive direction away from the limit, then reset the alarm.
- 5
Confirm that the machine's reference position (zero return) has been correctly established for the affected axis.