EXCESS MAXIMUM ACCELERATION
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa DS0005 ?
This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the control detected a command specifying an acceleration value that exceeds the machine's maximum allowable acceleration for the axis.
Causas comunes
- NC program commands excessively high acceleration rates for the axis.
- Machine parameters for acceleration time constants or jerk limits are set too aggressively.
- Mechanical binding, excessive friction, or backlash preventing the axis from achieving commanded acceleration.
- Limitations of the servo amplifier or motor preventing the commanded acceleration.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review the NC program for any movements that imply excessively high acceleration, particularly during rapid changes in direction or speed.
- 2
Verify the machine's acceleration parameters for the affected axis (e.g., parameters related to acceleration time constants or jerk limits).
- 3
Inspect the mechanical system for any binding, excessive friction, or backlash that could prevent the axis from achieving commanded acceleration.
- 4
Check for any related servo alarms on the drive system that might indicate an inability to meet acceleration commands.
- 5
Adjust the acceleration parameters to more conservative values and test the machine's movement to prevent over-acceleration.