Traduciendo...
384

SOFT PHASE ALARM(EXT)

Fanuc · Series 0i-D/0i Mate-D Maintenance

¿Qué significa 384 ?

This alarm on Fanuc Series 0i-D/0i Mate-D indicates a position data alarm from a separate (external) detector. Causes typically include detector failure, environmental contamination, or issues with its mounting or cabling.

Causas comunes

  • Internal failure of the external detector affecting position data accuracy.
  • Environmental contamination (e.g., cutting fluid, dust) affecting the detector's operation.
  • Mechanical misalignment or instability of the external detector.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the external detector for signs of environmental contamination (e.g., cutting fluid, dust) that could interfere with its operation.

  2. 2

    Verify the mechanical integrity and proper alignment of the external detector.

  3. 3

    Check the communication cable from the external detector to the SDU for any damage, loose connections, or improper shielding.

  4. 4

    If the alarm persists after thorough inspection and cabling checks, replace the external detector unit.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Series 0i-D/0i Mate-D Maintenance