Traduciendo...
383

PULSE MISS(EXT)

Fanuc · Series 0i-D/0i Mate-D Maintenance

¿Qué significa 383 ?

This alarm on Fanuc Series 0i-D/0i Mate-D indicates a small internal signal amplitude from a separate (external) detector. This can be caused by the detector itself failing, power supply issues, or external electrical noise affecting the signal integrity.

Causas comunes

  • Internal failure of the external detector causing weak signal output.
  • Insufficient or unstable power supply voltage to the external detector.
  • Damaged or degraded cable from the detector to the SDU, reducing signal amplitude.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the external detector's power supply voltage at the detector terminals to ensure it is within specified limits.

  2. 2

    Verify the integrity of the cable connecting the detector to the SDU, checking for damage or signal attenuation.

  3. 3

    Check for any significant electromagnetic interference (EMI) near the detector or its cabling that could affect signal amplitude.

  4. 4

    If power, cabling, and noise issues are ruled out, replace the external detector unit.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Fanuc Series 0i-D/0i Mate-D Maintenance