FB MUTING Bit 10

Muting Input 3/4 Discrepancy Not Reset

Beckhoff · TwinSAFE Logic FB

¿Qué significa FB MUTING Bit 10 ?

A discrepancy error in 'MuteIn3'/'MuteIn4' was detected and has not yet been acknowledged or reset. This indicates a persistent underlying issue with muting input group 2 that needs active resolution and acknowledgment before normal operation can resume. The system will remain in a safe, stopped state.

Causas comunes

  • Muting input 3 or 4 discrepancy not reset.
  • Safety light curtain muting signal conflict.
  • Muting sensors reporting inconsistent states.
  • Muting signal lost while safety function is active.
  • External muting logic not acknowledged.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Address the root cause of the 'MuteIn3'/'MuteIn4' discrepancy (refer to troubleshooting for 'FB MUTING Bit 2').

  2. 2

    Ensure the error is acknowledged via the 'ERR_ACK' input of the related TwinSAFE group after rectifying the fault.

  3. 3

    Verify that the physical conditions causing the discrepancy are no longer present (e.g., sensor issue resolved, wiring fixed).

  4. 4

    Monitor the 'MuteIn3' and 'MuteIn4' signals to confirm stable, synchronized operation after troubleshooting.