Press Not Moving After Start Command
Beckhoff · TwinSAFE Logic FB
¿Qué significa 0x401F ?
The PressStarted input was TRUE, commanding the press to move, but the position did not change (or 'Stopped' did not become FALSE) within the PressStartedDelayTime. This indicates a failure to initiate motion after the start command, potentially due to a mechanical jam or drive issue, preventing operation.
Causas comunes
- Press mechanism did not move after receiving a start command.
- Actuator or motor failed to engage.
- Insufficient power supply to the drive system.
- Mechanical obstruction preventing movement.
- Faulty start command signal or logic.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the mechanical system for obstructions, jams, or insufficient power/force to initiate movement.
- 2
Verify the motor, actuator, and associated power components for correct operation and wiring.
- 3
Inspect the position sensor to ensure it is detecting movement correctly and not stuck at a fixed value.
- 4
Review the PressStartedDelayTime parameter to ensure it is adequately set for the expected start-up sequence.