4065
Test move will take too long
ABB · Application Error ABB Motion Drives Error trouble shoo
¿Qué significa 4065 ?
A test move operation has been initiated which the drive determines will take an excessive amount of time to complete. This is often due to incorrect scaling parameters or an improperly configured test move velocity.
Causas comunes
- Test move duration parameters are set to an overly long value.
- Incorrect SCALEFACTOR setting, leading to miscalculation of move distance or time.
- Motor or application mechanics causing unexpected resistance or limited movement.
- Low velocity limits preventing the move from completing within a reasonable timeframe.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review the test move parameters in Mint Workbench and adjust them to a reasonable duration.
- 2
Verify that the SCALEFACTOR parameter is correctly configured according to the application's mechanical setup and units.
- 3
Check for any mechanical binding or obstruction in the motor and load system that might impede motion.
- 4
Ensure that velocity limits are appropriate for the test move and do not restrict it excessively.
Datos técnicos verificados. Última actualización: March 2026