247

Event not supported

ABB · Application Error ABB Motion Drives Error trouble shoo

¿Qué significa 247 ?

The Mint program attempted to use an event that is not supported by the current controller hardware or firmware version (MotiFlex e100, MotiFlex e180, MicroFlex e190).

Causas comunes

  • Attempting to use an event that is not available on the specific controller model or its firmware version.
  • Using an event that has been deprecated or changed in a newer firmware version without updating the program.
  • The drive's hardware platform does not possess the necessary capabilities for the invoked event.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Amend the Mint program to use only events that are supported by the specific controller model and its current firmware version.

  2. 2

    Consult the drive's firmware release notes or Mint programming manual to verify event compatibility for your hardware.

  3. 3

    If possible, update the controller's firmware to a version that supports the desired event, or modify the program to use an alternative, supported event.

  4. 4

    Review the error log for any additional information regarding the unsupported event.

Ver todos los códigos en este manual (58)
Datos técnicos verificados. Última actualización: March 2026