246

Event not present/installed

ABB · Application Error ABB Motion Drives Error trouble shoo

¿Qué significa 246 ?

The Mint program attempted to reference an event that is not present, has not been installed, or is undefined in the controller (MotiFlex e100, MotiFlex e180, MicroFlex e190).

Causas comunes

  • Referencing a non-existent or undefined event within the Mint program.
  • A typographical error in the event name used in the Mint program.
  • A required event definition or library file is missing or not loaded.
  • Attempting to use an event that is not supported by the current firmware version.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Amend the Mint program to ensure that all referenced events are correctly defined and installed.

  2. 2

    Double-check the spelling and syntax of the event name in the Mint program against its official definition.

  3. 3

    Verify that any necessary event libraries or modules are loaded and accessible by the program.

  4. 4

    Consult the Mint programming manual or drive documentation to confirm the correct declaration and usage of events.

Ver todos los códigos en este manual (58)