What does CPF11 mean?

A fault was detected in the drive's Random Access Memory (RAM), which is used for temporary data storage during operation. This can lead to unstable drive performance.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Verify supply voltage at the drive's input terminals (L1, L2, L3) for stability and conformity to drive specifications.

  2. 2

    Inspect the drive's operating environment, ensuring proper ventilation and that the ambient temperature is within specified limits.

  3. 3

    Check the drive's firmware version and verify it is the latest recommended version for the application from Yaskawa.

  4. 4

    Perform a controlled power cycle of the drive, removing main power for at least 30 seconds before reapplying.