InF9

Current Measurement Circuit Error

Schneider Electric · Altivar Machine ATV320 Variable Speed Drive

What does InF9 mean?

A detected error in the internal current measurement circuit. This is critical as the drive relies on accurate current feedback for motor control and protection. Inaccurate measurements can lead to incorrect torque, motor damage, or unstable operation.

Common Causes

  • The internal current measurement circuit is faulty or reporting abnormal values.
  • Defective current sensing transducers (e.g., Hall effect sensors).
  • Calibration error in the current measurement circuitry.
  • Short circuit or open circuit in the current sense feedback loop.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Power cycle the drive.

  2. 2

    Check for any signs of physical damage to the drive's power board or current sensors.

  3. 3

    Perform a motor auto-tuning procedure to recalibrate current sensors if possible and supported.

  4. 4

    If the fault persists, it likely indicates a failure of the internal current measurement hardware, requiring repair or replacement.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026