MR7

Alarm Space 7 Violation

Kuka · KK53Y Servo Motor

What does MR7 mean?

The MR7 signal indicates a violation of monitoring space 7. A '0' state on this signal means that monitoring space 7 is currently being infringed upon. If monitoring space 7 is intentionally inactive, the system considers it violated by default, and the associated safe output MR7 will be in the '0' state.

Common Causes

  • Alarm condition triggered in Space 7 of the monitoring system.
  • Parameter P7 has exceeded its defined alarm threshold.
  • Sensor associated with Space 7 reporting an out-of-bounds value.
  • Configuration error in Space 7 alarm limits.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Identify the configured boundaries for monitoring space 7 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 7.

  3. 3

    If monitoring space 7 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR7 signal will default to a '0' (violated) state.

Browse all codes in this manual (17)
Verified technical data. Last updated: March 2026

Related Faults