F873
Power Supply Driver Stage Fault
Indramat · ECODRIVE Controller
What does F873 mean?
The voltage supply for the ECODRIVE DKC01.1/DKC11.1 drive's internal driver stage is monitored. If this voltage is detected as too low, the drive is turned off to prevent damage.
Common Causes
- Voltage supply of the driver stage is too low, indicating an internal fault within the drive controller.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the incoming main AC supply voltage to the ECODRIVE DKC01.1/DKC11.1 drive controller is stable and within specified limits.
- 2
Inspect for any external factors that might cause internal voltage drops, such as extreme ambient temperatures or blocked cooling vents.
- 3
If external conditions are normal and the fault persists, it indicates an internal hardware fault; exchange the ECODRIVE DKC01.1/DKC11.1 drive controller.