60

Cooling

Vacon · NX Liquid-Cooled Drive

Was bedeutet 60 ?

The 'Cooling OK' digital input, typically used for liquid cooling feedback, has triggered this fault, indicating an issue with the cooling system status.

Häufige Ursachen

  • General cooling system fault.
  • Cooling fan speed below minimum threshold (P0315).
  • Overheating detected by internal temperature sensors.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the liquid cooling system for proper operation, ensuring adequate flow, pressure, and temperature within specified limits.

  2. 2

    Verify the signal wiring connecting the cooling system's 'Cooling OK' feedback sensor to the drive's digital input.

  3. 3

    Check the status and functionality of the 'Cooling OK' input itself, ensuring the sensor is operating correctly.