16

Motor over temperature

Vacon · 20 Compact

Was bedeutet 16 ?

The frequency converter's internal motor temperature model has detected that the motor is overheating. This fault primarily indicates that the motor is operating under an overload condition.

Häufige Ursachen

  • Motor winding temperature exceeds limit.
  • Overload condition sustained for too long (P1-07).
  • Faulty motor temperature sensor (PTC or KTY).
  • Inadequate motor cooling (e.g., blocked fan).
  • High ambient temperature around the motor.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Decrease the mechanical load applied to the motor.

  2. 2

    If no motor overload is present, check and adjust the motor temperature model parameters within the frequency converter's settings (e.g., thermal time constant).