F110
Ex-e protection
SEW Eurodrive · MOVITRAC 07B System
Was bedeutet F110 ?
The maximum allowed duration for operating the motor below 5 Hz in Ex-e protection mode has been exceeded. This fault initiates an emergency stop to comply with safety regulations for explosion-protected motors, which have thermal limitations at low speeds.
Häufige Ursachen
- Project planning or application design dictates extended motor operation below 5 Hz
- Operational conditions caused the motor to run at very low frequencies (below 5 Hz) for too long
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review the application's project planning to ensure compliance with Ex-e motor operating limits below 5 Hz.
- 2
Modify the control logic or process to shorten the duration of motor operation below 5 Hz.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026