Übersetzen...
97
Copy error
SEW Eurodrive · MOVIFIT-FC Inverter
Was bedeutet 97 ?
An error occurred during data transmission or copying process. This could happen during parameter transfer or other data-intensive operations, indicating corrupted or incomplete data writes.
Häufige Ursachen
- Data corruption during parameter copy between memory modules.
- CRC check failed for copied parameter set.
- Incomplete data transfer during configuration upload.
- Firmware mismatch between source and destination.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Repeat the copying process.
- 2
Set the unit to delivery status (factory defaults) and reset all unit parameters.
- 3
Reset the fault by switching off the DC 24 V supply voltage.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: SEW Eurodrive MOVIFIT-FC Inverter