01

Overcurrent in output stage

SEW Eurodrive · MOVIFIT-FC Inverter

Was bedeutet 01 ?

This fault indicates an overcurrent condition on the inverter output. It is typically caused by a short circuit in the connection between the inverter and the motor, or a short circuit within the motor winding itself. Excessive current flow from the inverter can lead to damage if not addressed.

Häufige Ursachen

  • Motor drawing excessive current exceeding output stage limits.
  • Short circuit in motor windings.
  • Incorrect motor tuning parameters (e.g., P0307, P0311).
  • Mechanical overload or jamming of the driven equipment.
  • Output stage power components failure.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the connection between the inverter output and the motor for short circuits.

  2. 2

    Check the motor winding for short circuits.

  3. 3

    Reset the fault by switching off the DC 24 V supply voltage.