81
Start condition/output open
SEW Eurodrive · MOVIFIT-FC Inverter
Was bedeutet 81 ?
This fault indicates an issue with the start condition, specifically relevant in hoist operation mode, or an open circuit in the output. It could be due to a phase failure in the motor lead preventing proper startup or operation.
Häufige Ursachen
- Start command sent but output contact failed to close.
- Feedback signal from output contact is missing or incorrect.
- Wiring issue preventing output contact closure.
- Mechanical obstruction of the output contact.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the motor lead for phase failure.
- 2
Reset the fault by switching off the DC 24 V supply voltage.