F032
Invalid configuration
Schindler · Easy Altivar ATV310 Drive
Was bedeutet F032 ?
This fault signifies that the configuration loaded into the drive, typically via the bus or a communication network, is inconsistent. It can also be triggered if the configuration upload process was interrupted or did not complete successfully.
Häufige Ursachen
- The configuration loaded in the drive via the bus or communication network is inconsistent or corrupted.
- The configuration upload process was interrupted before completion.
- An attempt was made to load an incompatible configuration file into the drive.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the integrity and compatibility of the configuration file that was previously loaded.
- 2
Load a known compatible and validated configuration into the drive.
- 3
Ensure stable communication during configuration upload to prevent interruptions.