A-17

Key alarm

Schindler · Easy Altivar ATV310 Drive

Was bedeutet A-17 ?

The Key alarm indicates an issue with the display terminal's keypad. This fault is triggered if a key remains pressed for longer than 10 seconds, if the membrane switch is disconnected, or if the display terminal powers on while a key is already depressed.

Häufige Ursachen

  • A key on the display terminal is stuck in the pressed position for an extended period (over 10 seconds).
  • The membrane switch of the display terminal is disconnected or has failed internally.
  • The display terminal was woken up or powered on with one or more keys already pressed.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the display terminal keypad for any physically stuck keys and gently clean around them to ensure free movement.

  2. 2

    Check the connection of the membrane switch to the display terminal's PCB, ensuring it is properly seated.

  3. 3

    Ensure no keys are pressed when the display terminal is powered on or woken up.

  4. 4

    If the fault persists after checking the keypad, consider replacing the display terminal as the membrane switch or internal components may be faulty.