F003
Unknown or incompatible power board
Schindler · Easy Altivar ATV310 Drive
Was bedeutet F003 ?
This ATV310 fault indicates that the installed power card is incompatible with the control card. This prevents the drive from operating correctly and points to an incorrect or mismatched power section component.
Häufige Ursachen
- The power card installed in the drive is incompatible with the control card
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Turn the ATV310 drive off and then back on again after waiting for at least 5 minutes to ensure a full reset.
- 2
Check the input power supply to the drive for stability and ensure correct voltage levels are present.
- 3
Visually inspect the drive for any obvious signs of physical damage or loose connections on internal cards.
- 4
Contact local Schneider Electric representative for power board compatibility verification and potential replacement.