Err1
Speed Reference Error Fault
Schindler · Altivar 212 Variable Frequency Drive
Was bedeutet Err1 ?
This fault is triggered when parameters related to VIA or VIB analog input speed reference points are set improperly, leading to an inconsistent or erroneous speed command from the Altivar 212 drive.
Häufige Ursachen
- Parameters F202 ([VIA freq. point 1]), F203 ([VIA ref point 2]), F210 ([VIB ref. point 1]), or F212 ([VIB ref. point 2]) are set improperly.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify and set parameters F202, F203, F210, and F212 to their correct settings according to the application requirements.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Schindler Altivar 212 Variable Frequency Drive