EEP2
EEPROM Error 2 Fault
Schindler · Altivar 212 Variable Frequency Drive
Was bedeutet EEP2 ?
This fault occurs if power was removed from the Altivar 212 drive during a parameter reset operation, leading to a data writing error in the EEPROM. It can also indicate issues with initial position detection or motor inductance during auto-tuning.
Häufige Ursachen
- Power removed from the drive during a parameter reset operation, causing a data writing error.
- Measured current at initial position detection during auto-tuning is too small or large according to the motor's inductance or output phase loss.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Cycle power to the drive to clear the detected fault.
- 2
Attempt the parameter reset operation again.
- 3
If the detected fault persists after re-attempt, contact Schneider Electric to repair the drive.