Low read-back volts from DC bus circuit.
Otis · DSD 412 Elevator System
Was bedeutet 938 ?
This fault indicates that a low voltage read-back is detected from the DC bus circuit. This can occur during Self-Tune (Function #997) or Self-Diagnostic (Function #998). For drives larger than 300 amps DC, this involves discrete wires.
Häufige Ursachen
- Missing wire connected to the bus voltage feedback circuit.
- Component problem where the feedback voltage divider ratio does not match the one identified in the Cube ID PCB.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check for any missing wires connected to the bus voltage feedback circuit.