403

FIVE-MINUTE FULL FIELD

Otis · DSD 412 Elevator System

Was bedeutet 403 ?

This fault indicates that the Drive and Field Enable control circuit at terminal TB1-9 remained active for five minutes without the drive commencing operation. This condition can lead to burnout of the motor field winding.

Häufige Ursachen

  • Issue with the car controller relay logic, incorrectly keeping the Drive and Field Enable active without a start command.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the car controller relay logic to ensure that the Drive and Field Enable signal at TB1-9 is not continuously active for prolonged periods without the drive being started.