E.LF

Output phase loss

Mitsubishi Electric · Mitsubishi FR-E800 Variable Frequency Drive

Was bedeutet E.LF ?

The inverter output is shut off if one of the three phases (U, V, W) on the output side (motor/load side) is lost. This typically indicates a broken wire, loose connection, or open circuit in the motor wiring, leading to unbalanced currents and potential motor overheating.

Häufige Ursachen

  • Output phase loss detected.
  • One or more output phases (U, V, W) are disconnected.
  • Open circuit in motor power cable.
  • Fault in the output stage of the inverter.
  • Loss of feedback from one of the motor phases.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the motor wiring thoroughly for proper connections and continuity across all three phases.

  2. 2

    Ensure that the capacity of the motor used is not smaller than that of the inverter, which can sometimes lead to phase loss detection issues.

  3. 3

    If using PM sensorless vector control, ensure a start command is not given while the motor is coasting; allow the motor to stop first or utilize the automatic restart/flying start function.