E38
Outside Air Temperature Sensor (ThoA) Defective / Poor Connection
Mitsubishi Electric · FR-D700 Inverter
Was bedeutet E38 ?
The outside air temperature sensor (ThoA) is defective (open circuit resistance) or has a poor connection on the outdoor unit PCB. This compromises the system's ability to accurately sense ambient conditions and adjust operation.
Häufige Ursachen
- Outside air temperature sensor (ThoA, e.g., P16) is defective.
- Poor electrical connection to the ThoA sensor.
- Sensor reading is incorrect or intermittent.
- Wiring to the sensor is compromised.
- Extreme ambient temperatures affecting sensor performance.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Measure the resistance of the outside air temperature sensor (ThoA) and compare to the specified temperature-resistance chart.
- 2
Inspect the ThoA sensor connector on the outdoor unit PCB for secure connection and check for wire damage.