Übersetzen...
SP9051

LOW VOLT POWER CIRCUIT

Fanuc · Series 0i-D/0i Mate-D Maintenance

Was bedeutet SP9051 ?

This Fanuc Series 0i-D/0i Mate-D spindle alarm indicates that an input voltage drop was detected in the power circuit (Power Supply (PS) alarm indication: 4). This typically signifies a momentary power failure or poor contact in the magnetic contactor (MC).

Häufige Ursachen

  • Input power supply voltage drop or sag affecting the spindle amplifier/PS unit.
  • Momentary power failure or interruption of the AC supply.
  • Poor contact, wear, or failure in the main magnetic contactor (MC) supplying power.
  • Loose or corroded power wiring connections to the spindle amplifier or PS unit.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Measure the incoming three-phase AC power supply voltage to the spindle amplifier (or PS unit) to confirm it is stable and within specifications.

  2. 2

    Inspect the main magnetic contactor (MC) for signs of wear, pitting, or poor contact; check its coil operation and auxiliary contacts.

  3. 3

    Check all power wiring connections from the main supply breaker through to the spindle amplifier for looseness or corrosion.

  4. 4

    Monitor the power supply for momentary voltage sags or interruptions, especially during machine operation or startup.

  5. 5

    If the magnetic contactor shows signs of failure or malfunction, replace it with an equivalent unit.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc Series 0i-D/0i Mate-D Maintenance