365
BROKEN LED(INT)
Fanuc · Series 0i-D/0i Mate-D Maintenance
Was bedeutet 365 ?
This alarm on Fanuc Series 0i-D/0i Mate-D with αi/βi Pulsecoders indicates an LED disconnection within the built-in Pulsecoder. This typically points to an internal failure of the Pulsecoder's optical components.
Häufige Ursachen
- Internal failure of the Pulsecoder's LED component.
- Degradation of the Pulsecoder's optical system.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Visually inspect the Pulsecoder for any external physical damage or signs of impact.
- 2
Verify that the Pulsecoder cable is securely connected at both the Pulsecoder and the servo amplifier.
- 3
Check the diagnostic LEDs or alarm codes on the servo amplifier for additional information.
- 4
If the alarm persists after verifying connections and no external damage is visible, replace the Pulsecoder unit.