IE0003

+ OVERTRAVEL ( SOFT 2 )

Fanuc · Series 0i-D/0i Mate-D Maintenance

Was bedeutet IE0003 ?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 2 on the positive side for an axis has been exceeded. This is a secondary software limit, often used for specific work zones or fixtures.

Häufige Ursachen

  • NC program error commanding movement beyond the positive software limit 2.
  • Incorrect setting of the software limit parameter for positive stroke check 2.
  • Interference with a fixture or workpiece within the defined stroke check 2 area.
  • Manual operation inadvertently exceeding the positive software limit 2.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Review the NC program for commands that attempt to move the axis beyond the positive limit defined by stored stroke check 2.

  2. 2

    Verify the parameter settings for stored stroke limit check 2 on the positive side for the specific axis.

  3. 3

    Check for any physical obstructions or workholding fixtures that might be within the defined stroke check 2 area.

  4. 4

    Temporarily jog the axis in the negative direction, then reset the alarm to clear the overtravel condition.

  5. 5

    Ensure that machine coordinates are accurate and properly calibrated before resuming operation.