Übersetzen...
IE0002

- OVERTRAVEL ( SOFT 1 )

Fanuc · Series 0i-D/0i Mate-D Maintenance

Was bedeutet IE0002 ?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 1 on the negative side for an axis has been exceeded. This is a software limit violation.

Häufige Ursachen

  • NC program error commanding movement beyond the negative software limit 1.
  • Incorrect setting of the software limit parameter for negative stroke check 1.
  • Manual operation or jog movement exceeding the defined negative software limit 1.
  • Tool length offsets or work offsets are incorrectly applied, causing an apparent overtravel.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the NC program for coordinate values or movements that exceed the defined negative software limit 1 for the affected axis.

  2. 2

    Verify the parameter setting for the negative software limit 1 for the specific axis, ensuring it is correctly configured.

  3. 3

    Ensure that tool length offsets or work offsets are accurately entered and do not cause an overtravel condition.

  4. 4

    In manual mode, jog the affected axis in the positive direction away from the limit, then reset the alarm.

  5. 5

    Confirm that the machine's reference position (zero return) has been correctly established for the affected axis.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc Series 0i-D/0i Mate-D Maintenance