OBJECT UNMATCH
Fanuc · Series 0i-D/0i Mate-D Maintenance
Was bedeutet ER08 ?
This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that an unsupported function is used within the sequence program (ladder program). This means the PMC model or its firmware does not support a specific command or feature in the program.
Häufige Ursachen
- The sequence program uses a function or command not supported by the specific PMC model.
- The PMC's firmware version does not include support for certain advanced functions used in the program.
- The sequence program was developed for a different, more capable PMC model.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review the sequence program to identify any advanced or specific functions that might not be compatible with the current PMC model or its firmware version.
- 2
Verify the PMC model and firmware version installed on the machine against the requirements of the sequence program.
- 3
Attempt to simplify or rewrite the section of the sequence program using the unsupported function with standard PMC logic.
- 4
Consult the FANUC PMC programming manual for the specific PMC series to confirm supported functions and their proper syntax.
- 5
If simplifying the program is not feasible, contact FANUC support to inquire about PMC firmware updates or compatible PMC modules that support the required function.