ER03

PROGRAM SIZE ERROR(OPTION)

Fanuc · Series 0i-D/0i Mate-D Maintenance

Was bedeutet ER03 ?

This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that the sequence program's size exceeds the limits specified by the currently active ladder step count option. This makes the sequence program invalid.

Häufige Ursachen

  • The sequence program's step count exceeds the activated ladder step count option.
  • An incorrect or insufficient ladder step count option is specified or installed.
  • Recent program modifications increased the size beyond the current option's capacity.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Review and optimize the sequence program to reduce its step count, removing any unnecessary logic or redundant sections.

  2. 2

    Verify the current ladder step count option installed on the PMC and confirm it aligns with the program's requirements.

  3. 3

    Check if a different, larger capacity ladder step count option is available for installation or activation.

  4. 4

    If the program cannot be reduced further and the current option is insufficient, consult FANUC for upgrading the ladder step count option.

  5. 5

    Ensure that the PMC programmer used to create or load the sequence program is configured for the correct PMC type and option.