Übersetzen...
SRVO-009

Pneumatic Pressure Alarm

Fanuc · R-30iB Mate + Mate Plus Robot

Was bedeutet SRVO-009 ?

An abnormal air pressure condition has been detected. This input signal is typically located on the end effector (EE) interface of the robot, indicating an issue with the pneumatic supply to or within the robot's tooling.

Häufige Ursachen

  • An alarm related to pneumatic pressure has been triggered.
  • This could mean that the compressed air supply pressure is too low, too high, or fluctuating outside the acceptable range for machine operation.
  • Low pressure can affect actuators and grippers, while high pressure can damage components.
  • Check the air compressor, pressure regulators, and airline for blockages or leaks.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the cause of the abnormal air pressure.

  2. 2

    Check the EE connector for proper connection and damage.

  3. 3

    Check the robot connection cable (RMP1, RP1) and the internal cable of the robot for a ground fault or a cable disconnection; if a fault is detected, replace the cable.

  4. 4

    Replace the 6-Axis servo amplifier.

  5. 5

    Replace the internal cables of the robot.

Alle Codes in diesem Handbuch durchsuchen (53)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc R-30iB Mate + Mate Plus Robot