Übersetzen...
ALM LED Blink (1:1)

Broken Wire or Noise (Subsequent Unit)

Fanuc · R-30iB Mate + Mate Plus Robot

Was bedeutet ALM LED Blink (1:1) ?

The red ALM LED blinks with a 1:1 duty cycle (0.5s ON / 0.5s OFF), indicating a broken wire or poor cable connection between the unit of interest (JD1A connector) and a subsequent unit (JD1B connector). Electromagnetic noise around the cable is also a potential contributing factor to this communication issue.

Häufige Ursachen

  • A broken wire or significant electrical noise is disrupting communication with a subsequent unit or module.
  • The signal integrity on the communication bus to a connected device (e.g., I/O expander, remote axis) has been compromised.
  • This could be due to damaged cabling, poor shielding, or interference from external electrical sources.
  • The control system is unable to reliably receive or transmit data from the affected downstream unit.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check for a defective cable or a poor cable connection between JD1A on the unit of interest and JD1B on a unit subsequent to that unit.

  2. 2

    Check to see if there is noise present around the cable.

Alle Codes in diesem Handbuch durchsuchen (53)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc R-30iB Mate + Mate Plus Robot