Fanuc · R-30iB Mate + Mate Plus Robot

Was bedeutet OPEN ?

The OPEN (Green) LED indicates normal communication between the servo amplifier and the main board via FSSB. This fault occurs if the LED does not light, indicating a loss or abnormality in this critical communication link. This could be due to a faulty optical cable, servo card, or the servo amplifier itself.

Häufige Ursachen

  • Fiber Optic Sensor System (FSSB) communication failure between controller and servo drives.
  • Damaged fiber optic cable or connectors in the FSSB loop.
  • Faulty servo drive or controller interface card in the FSSB.
  • Interference affecting fiber optic signal transmission.
  • Incorrect FSSB addressing or configuration.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the connection of the FSSB optical cable.

  2. 2

    Replace the servo card.

  3. 3

    Replace the servo amplifier.