Übersetzen...
E3104

Plausibility error of safety parameters

Bosch Rexroth · IndraDrive Troubleshooting

Was bedeutet E3104 ?

This warning occurs in normal operation when safety technology is activated. It indicates a comparison showed that channel 1 and channel 2 are not operating with the same safety parameters. If a safety function is selected, this condition would trigger the F3140 Plausibility error of safety parameters error.

Häufige Ursachen

  • Channel 1 and channel 2 are not working with the same safety parameters.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Execute command P-0-3204 (Synchronize and store safety technology IDN command) to make channel 2 accept the parameters of channel 1.

Alle Codes in diesem Handbuch durchsuchen (16)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Bosch Rexroth IndraDrive Troubleshooting