E3103

Dynamization failed

Bosch Rexroth · IndraDrive Troubleshooting

Was bedeutet E3103 ?

This warning occurs in normal operation when safety technology is activated. It indicates that no dynamization pulse occurred at the dynamization input within the time P-0-3223, Time interval for dynamization of safety function selection, or the pulse width deviates from P-0-3224, Duration of dynamization pulse of safety function selection. If a safety function is selected, this condition would trigger F3134 Dynamization time interval incorrect or F3135 Dynamization pulse width incorrect errors.

Häufige Ursachen

  • No dynamization pulse occurs at the dynamization input within the time P-0-3223.
  • The pulse width at the dynamization input differs from the parameterized time P-0-3224.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Remove the cause of the error in the wiring of the dynamization input.