A88A

Value counter 1

ABB · ACS880

What does A88A mean?

Warning generated by value counter 1, indicating a predefined count threshold has been reached for a monitored value. This is often used for tracking production cycles, material usage, or other process-related counts. Overlooking this could lead to process deviations or component wear.

Common Causes

  • Value counter 1 (Parameter P4-07) has accumulated a monitored value (e.g., kWh, liters) that has reached its programmed threshold (P4-07.01 Value Count 1 Limit).
  • The input source providing the value to the counter (e.g., an analog input, internal calculation) is operating as expected.
  • The threshold value in P4-07.01 was configured incorrectly or requires adjustment based on new operational targets or reporting periods.
  • The counter was not reset after reaching its limit in a previous monitoring cycle.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Determine the type of value being tracked by Value Counter 1 (e.g., energy consumption, production units) by checking related documentation or P4-07.00 (Current Value 1).

  2. 2

    Record the current accumulated value from parameter P4-07.00 (Current Value 1) for reporting, inventory, or billing purposes.

  3. 3

    Perform any scheduled actions (e.g., material reorder, energy efficiency review) related to the accumulated value.

  4. 4

    Reset Value Counter 1 to zero by setting parameter P4-07.02 (Reset Counter 1) to '1' (Execute) after completing the required actions.

  5. 5

    Adjust the limit in parameter P4-07.01 (Value Count 1 Limit) if the monitoring threshold needs to be revised.

Browse all codes in this manual (116)
Verified technical data. Last updated: March 2026

Related Faults