Speed Deviation
Yaskawa · GA500 Maintenance and Troubleshooting
What does dEv mean?
The drive detected a significant deviation between the commanded speed reference and the actual detected speed, exceeding the set threshold (F1-10) for longer than the specified delay (F1-11). This indicates a problem with the motor's ability to follow the speed command, potentially leading to process disruption, mechanical stress, or loss of control.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Adjust the speed deviation detection level (F1-10) and delay time (F1-11) if they are overly sensitive for the application.
- 4
Inspect the machine for any mechanical lock-ups, obstructions, or excessive friction that could be hindering motor rotation.
- 5
Ensure that the motor's holding brake (if present) is fully released and not dragging when the drive is commanded to run.