3803
The PV array current is too high
SMA · SUNNY CENTRAL 500CP XT / 630CP XT Solar Inverter
What does 3803 mean?
The current from the PV array has exceeded its maximum permissible level. This can indicate an over-dimensioned array or a fault condition leading to excessive current. This will cause the inverter to shut down for 1 minute and reset automatically on day change.
Common Causes
- Excessive DC input current from the PV array.
- Incorrect module wiring or system design leading to overcurrent.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check the DC input current of the PV array.
- 2
Review the module wiring and system design to ensure current limits are not exceeded.
- 3
Verify that the PV array's maximum power point voltage (Vmp) and short-circuit current (Isc) are within the inverter's specifications.