Encoder 3: Serial communications error
Siemens · SINUMERIK 828D CNC Control
What does 233110 mean?
This error signifies a transfer fault within the serial communication protocol between Encoder 3 and its evaluation module. The specific cause can range from incorrect quiescent levels, encoder unresponsiveness, CRC errors, acknowledgment errors, internal driver errors, timeout, or issues with the data line or parameterization, as indicated by fault bits in r0949. Such communication errors will lead to loss of position feedback, rendering precise motor control impossible and potentially causing uncontrolled movement or system shutdowns if not resolved.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Update the firmware for the Sensor Module if a timeout occurs during cyclic reading.
- 4
Verify parameterization settings (p0429.2, p0449, p0436, p0429.6) as indicated by specific fault bits for protocol length, receive buffer, frame, or parity errors.
- 5
Inspect the data line for physical damage, incorrect connections, or signal level errors.