230672
SI CU: Control Unit software incompatible
Siemens · SINUMERIK 828D CNC Control
What does 230672 mean?
The existing Control Unit software does not support the safe drive-based motion monitoring function, leading to a STOP A that cannot be acknowledged. The fault value (r0949) is typically for internal Siemens troubleshooting. This indicates a fundamental incompatibility between the CU's software version and the attempted safety function.
Additional Steps
Steps 1–2 are listed in Priority Fix.
- 3
Upgrade the Control Unit software to a version that provides full support for the required safe motion monitoring functionality.
- 4
If necessary, consult Siemens documentation or support to ensure hardware and software compatibility for the desired safety functions.
Source: Siemens SINUMERIK 828D CNC Control